top of page
Picture3.jpg

intumescent coating

(factory)

lincoln

Apply Mordant Wash and one coat of Macrpoxy K267 Primer to all galvanised steelwork.

 

Apply to all steelwork Firetex FX1003/FX1005/FX5062 intumescent coating to give 90/120 minutes fire protection.

 

Apply Acrolon 7300 topcoat.

Picture6.jpg